South African mining technology for conveyance chairing & impact energy absorption.  
 
home technogrid levelok oleo acla gantrail "A" type rail contact
 
technogrid®
Energy Absorption DATA SHEET

Download the information on this page as an Adobe Acrobat pdf file (184kb)

Always use M20 Grade 8.8 bolts for installing the technogrids.

2 Mounting Holes 22 Diam Top and Bottom



MAX ENERGY
(kJ)
MAX STROKE
(mm)
MAX END
FORCE (kN)
DIM A
(mm)(±10mm)
12
135
150
540
24
270
150
836
36
405
150
1132
48
540
150
1428
60
675
150
1724

The Technogrid shown with and without covers



Force/energy/size relationships are not limited to what is illustrated here. For custom requirements please contact our Technical Sales Consultant.

Some typical force/energy/stroke relationships are shown on the 120kJ Technogrid graph. For example: the 120kJ unit shows the correlation energy (75kJ), the end force (235kN) and a stroke of 475mm is indicated.



12kJ Double Bar Technogrid


24kJ Double Bar Technogrid


48kJ Double Bar Technogrid


60kJ Double Bar Technogrid


120kJ Double Bar Technogrid
Tel: +27 11 974 1004 ::: Email: info@horne.co.za ::: www.horne.co.za